Early Access: The content on this website is provided for informational purposes only in connection with pre-General Availability Qlik Products.
All content is subject to change and is provided without warranty.
Skip to main content Skip to complementary content

TestEndpoint

General

URL

https://{host}/attunityenterprisemanager/api/v1/servers/{server} endpoints/{endpoint}?action=test&timeout={timeout}

Description

Contact an endpoint to test connectivity and configuration (permissions, CDC configuration).

HTTP method

GET

Required user role

See Required Enterprise Manager permissions.

Request parameters

Request parameters
Location Name Required Example

URL

Host [string]

Yes

computer.network.net

URL

ServerName [string]

Yes

myrepsrv1

URL

EndpointName [string]

Yes

TargetSQL1

URL

Timeout [int32]

Optional (default is 60 sec)

60 (seconds)

Header

EnterpriseManager.APISessionID [string]

Yes

wCo0_KvjEUFROvfHF5KGrw

Response body

{

"requeststate":"{enum requeststate_state}",

"message":""

"detailed_message":""

}

Response parameters

Response parameters
Name Description

state {enum endpoint_state]

The current state of the endpoint

message

Short description of the error

detailed message

Elaborate description of the error

cURL example

Request

c:\Tools\curl>curl -i -k --header "EnterpriseManager.APISessionID: wCo0_KvjEUFROvfHF5KGrw" "https://computer.network.net /attunityenterprisemanager/api/v1/servers/ myrepsrv1/endpoints/TargetSQL1c?action=test&timeout=60"

Response

HTTP/1.1 200 OK

Cache-Control: no-cache, no-store

Content-Length: 61

Content-Type: application/json; charset=utf-8

Server: Microsoft-HTTPAPI/2.0

Date: Sun, 19 Feb 2017 16:42:11 GMT

Payload

{

"state":"CONNECTED",

"error_message":""

}

Error response

Error responses
HTTP Code Enterprise Manager Code Text Description

500

AEM_TEST_ENDPOINT_CONNECTION_TIMEOUT

A timeout occurred while testing the connection for endpoint {endpoint} on Replicate server {server}.

Connection was not established within 60 seconds.

500

AEM_ENDPOINT_NOT_FOUND

Replicate endpoint {0} on server {1} could not be found.

The specified endpoint could not be found.

Did this page help you?

If you find any issues with this page or its content – a typo, a missing step, or a technical error – let us know how we can improve!